BetaTalk - The Renewable Energy and Low Carbon Heating Podcast
"Nathan is brilliant at making the complicated simple..." Amber Rudd (Secretary of State for Energy and Climate Change 2015-16)
BetaTalk is an award winning podcast for Local Authorities, Social Housing Groups, Think Tanks, Government, Journalists, Consultants, Developers, Gas, Oil and Heat Pump engineers and the general public.
It is hosted by Nathan Gambling who's family have been involved with heat pump technologies for nearly half a century.
"Nathan is one of the UK's clean heat leaders, so I always watch him closely..." Chris Stark (former CEO of the Climate Change Committee and Head of UK Gov. Mission Control)
The podcast features guests from the policy world as well as some of the UK's remarkable heating engineers. It discusses challenges and opportunities with decarbonised heating.
BetaTalk - The Renewable Energy and Low Carbon Heating Podcast
Measuring the Best Heat Pump System Designs
Measuring Heat pump system design with Brendon from Heacol
Link to slides for the test can be found here
THE TEST RIG
Brendon discusses how he first designed the test rig with Ulster University for testing the heat pump he had built which is specifically adapted for UK climate, the UK's building stock and how the homes in the UK are commonly heated e.g. a combi boiler.
When RHI was first introduced, it required heat pumps to have costly certification and sadly Brendon's heat pump had to be put on the back burner... after all, Brendon is extremely busy installing heat pumps for people and has been putting heat pumps in for many years.
(Note, if you are an investor in innovation you'd do well to contact Brendon to discuss this heat pump)
The test rig uses a 500L thermal store to simulate the internal of a property "it's got inertia, it's got thermal capacity and it's got buffer "
A plate heat exchanger connecting the thermal store to the heat pump simulates a radiator system which can have temps and flow rates changed.
Brendon describes how this set up is able to run different testing than the excellent Energy House at Salford University and benefit from quick responses to different heating stratagies and scenarios.
TESTING SYSTEM DESIGN
- testing a heat pump system with 3rd party controls and buffer tank
- testing a heat pump system with weather compensation and buffer tank
- testing a heat pump system with weather compensation and no buffer tank e.g. open zone or what has been called direct in the test which can be found here
The test simulated a house with an 11.5kW heat load.
With the first test the heat pump had to run at 50 degree Celsius flow to maintain an internal temp of 21 degrees.
In the second test the flow temp dropped to 45d.
The final test, with open zone system, no buffer and controlled with manufactures wether compensation controls only required a flow temp coming from the heat pump of 35 degrees C
Learn more about heat pump heating by following
Nathan on Linkedin, Twitter and BlueSky